Specifications of Besco gas lines

V profileM profile
DesignationGPG…7000 series
Diameters15–35 mm15–35 mm
Pressureup to 5 barup to 5 bar
Temperature−20…70 °C−20…70 °C
Medianatural gas, LPGnatural gas, LPG
StandardEN 1254-7EN 1254-7
ApprovalsDVGW, INiGDVGW, INiG
Catalogue items110101

How they differ from water fittings

Water press lines operate up to 16 bar and from −10 to 110 °C, while gas lines operate up to 5 bar and from −20 to 70 °C. Fittings from water lines are not used in gas installations, even if they match in size and profile. That is why it is worth keeping them separate in the warehouse and on the shelf, clearly labelled “gas”.

The V or M profile is chosen in the same way as for the water line, according to the customer’s press tool jaws. More in the guide V or M profile?.

Shapes in the V line (GPG)

Documents for customers

For gas installations, installers and investors ask about documents more often. We make approvals and declarations for the gas lines available to wholesalers in the document library after verification. The gas installation itself is carried out by a qualified installer in accordance with regulations.

Frequently asked questions

What are the parameters of Besco press fittings for gas?

Diameters 15–35 mm, pressure up to 5 bar, temperature from −20 to 70 °C, natural gas and LPG, standard EN 1254-7, DVGW and INiG approvals. In the V profile it is the GPG line, in the M profile the 7000 series.

Can press fittings from a water line be used for gas?

No. Fittings from water lines are not used for gas installations, even if they match in size and profile.

Who installs gas systems with press fittings?

A licensed installer, in line with regulations. We give wholesalers approvals and declarations for the gas lines in the document database after verification.

Data source: Besco Fittings & Connectors 2026 catalogue. As of 2026.

Call